journal of kerbala university, Volume 7, Issue 4, Pages 23-30

The study used magnetic water treatment to reduce bacterial contamination in drinking water tanks. Experiments was carried out using magnetic device with field intensity of (1000,1500,3000) Gauss. The devise was connected to one of the two plastic tanks used in this work. The tanks were connected to the same water source for three months. Water samples for both tanks were examined. The results indicated that a total bacterial count of (47 cuf /ml) in the control tank in comparison to the treated tank where the total bacterial count was (3 cuf /ml). and the transaction was severely 3000 Gauss is the most appropriate treatment in terms of the proportion of 95% removal. And also been studying some of the variables physicochemical such as color, smell , pH, turbidity and temperature. Through the foregoing results showed that bacterial contamination in the tank treatment was significantly reduced and not the survival of bacterial contamination in the reservoir show the intensity of magnetic (3000) Gauss, There were clear differences between results from both tanks indicating a successful physical treatment to reduce pollution in drinking water tanks