ISSN: 1813-0410

Author : Al-Awadi, Jaafer


Study of Chemical Oxygen Demand (COD) in Relation to Biochemical Oxygen Demand (BOD)

Hassony J . Abdulla; Nadia K . Bashar Al- Quraeshi; Firas Nabeeh; Jaafer Al-Awadi

journal of kerbala university, Volume 8, Issue 1, Pages 40-43

This investigation has been conducted to Study Chemical Oxygen Demand (COD) in Relation to Biochemical Oxygen Demand (BOD).Three replicates samples were taken in Baghdad city from :1 - From the water upper part of Army Channel , 2 –Near Al-Talbaia Bridge on Army Channel , 3 - Anaerobic main holes effluent (Septic systems) near Vegetables Station in Gamelia City , 4 –From Dyalia river near Ristmaia , 5 - From the intersection between Tigris and Dyalia river southern Baghdad , 6 - From Tigris river Near Bab –Al –Matham Bridge , 7- From Tigris river Near Al – AL-Aiemah Bridge and 8 –Waste water from Ristmaia Station before treatment .

Mean values of COD and BOD in the investigated locations show strong relation with high value of
correlation coefficient (r = 0.9758 ) and describe by the equation :
BOD= 6.1242 + 0.3142( COD ) + 0.0008 ( COD )²
The above formula used to estimate BOD depending on COD . The COD test can be run in a couple of hours instead of five days to determine BOD .